What is a Megohmmeter?
Megohmmeter is an electrical test instrument that measures very high resistance in insulation, usually in megohms. The instrument applies a controlled direct-current test voltage between conductors or between a conductor and ground. Electricians use the reading to find weakened, wet, contaminated, cracked, or aging insulation before leakage current creates shock, fire, or equipment problems.
Quick Facts About Megohmmeter
Category
Electrical insulation test instrument
Measured by
Megohms, or millions of ohms
Used for
Testing insulation resistance
Common confusion
It is not a standard continuity tester
Also called
Megger, Insulation resistance tester
Often discussed with
Electrical Wiring Repair, Commercial Electrical Repairs
Key Takeaways About Megohmmeter
- A megohmmeter measures insulation resistance at much higher values than a standard multimeter.
- Testing needs de-energized equipment and controlled access because the instrument applies test voltage.
- Low or declining resistance can show moisture, contamination, damage, or aging insulation.
- Readings must match equipment specifications, test conditions, and earlier results.
Understanding Megohmmeter

Megohmmeter is a specialized insulation resistance tester. It assesses insulation around wires, cables, motors, transformers, and other electrical equipment. A regular multimeter may show continuity or ordinary resistance. A megohmmeter measures resistance in the megohm range. One megohm equals one million ohms.
Related glossary terms: Resistance, Electrical Grounding, Lockout/Tagout.
The instrument helps reveal problems that a visual inspection may miss. Moisture, dirt, heat, chemical exposure, abrasion, and age can reduce insulation resistance. These problems may not cause an immediate short circuit. A high, stable reading usually shows that insulation works well. A low or falling reading calls for further investigation.
How Megohmmeter Works, Is Measured, or Is Used?
A megohmmeter applies a controlled direct-current test voltage between selected points. These points may include two conductors or one conductor and ground. The instrument measures small leakage current through the insulation. It then reports insulation resistance in megohms. The basic relationship follows Ohm's law. Resistance equals voltage divided by current.
Testing begins by identifying the circuit and disconnecting sensitive devices. The technician confirms that the equipment is de-energized. The technician connects the leads and applies the selected test voltage. They record the result with temperature and moisture conditions. After testing, the cable or equipment may retain an electrical charge. The technician safely discharges it before anyone handles the conductors.
Test voltage and connection points depend on the manufacturer's instructions. They also depend on the type of circuit. A technician may test conductor-to-conductor insulation. They may test conductor-to-ground insulation or separate cable sections. Digital instruments often record resistance over time. This record can show whether a result stays stable or changes.
Why Megohmmeter Matters?

Megohmmeter testing gives an early warning about insulation breakdown and unwanted leakage current. A circuit can pass a basic continuity check. Its insulation may still fail under a higher test voltage. Finding that weakness before energization can reduce several risks. These risks include nuisance trips, equipment damage, electric shock, or fire.
Results also support maintenance decisions. A single reading has limited value without key details. These details include equipment type, test voltage, temperature, and prior results. Comparing readings over time can show deterioration. A sudden change after water intrusion or overheating may require immediate isolation and repair.
When Megohmmeter Matters Most?
Megohmmeter use becomes especially useful after water exposure, flooding, or overheating. It also helps after long storage or suspected cable damage. It can help evaluate feeders, branch wiring, motors, generators, and other equipment. This testing can happen before equipment returns to service. Testing also helps during new installations, major repairs, and planned maintenance. A baseline reading can be recorded during these activities.
Safety controls matter because the instrument produces a test voltage. The tested circuit may hold a charge after testing ends. Only qualified personnel should select the test method and isolate equipment. They should protect nearby workers and disconnect sensitive electronics when required. A low reading shouldn't be dismissed as a bad meter. First, check lead connections, circuit isolation, test conditions, and manufacturer requirements.
How to Evaluate Megohmmeter?
- Confirm the circuit was isolated, locked out when required, and verified de-energized before testing.
- Record the test voltage, resistance reading, temperature, moisture conditions, and exact connection points.
- Compare the result with manufacturer instructions, project specifications, and earlier readings from the same equipment.
- Check whether sensitive electronics, surge protectors, controls, or connected devices were disconnected before applying test voltage.
- Investigate low, unstable, or sharply declining readings instead of relying on a single pass or fail label.
Related Concepts Compared
Megohmmeter vs. Insulation Resistance Tester
Insulation resistance tester is the functional description for a megohmmeter. The two terms usually refer to the same type of instrument.
Megohmmeter vs. Multimeter
A multimeter measures voltage, current, continuity, and ordinary resistance. A megohmmeter applies a higher controlled test voltage to assess insulation resistance.
Megohmmeter vs. Continuity Test
A continuity test checks whether a low-resistance path exists between points. It does not provide the same information about insulation leakage or high resistance.
Megohmmeter vs. Hi-pot Test
A hi-pot test checks whether insulation withstands a specified high voltage without breakdown. A megohmmeter measures insulation resistance and leakage behavior during the test.
Expert Note
A resistance reading is meaningful only with its test conditions. Temperature, moisture, cable length, connected equipment, and test duration can change the result. Record those details every time, and compare like with like before deciding that insulation has failed.
Common Mistakes or Myths About Megohmmeter
- Applying a megohmmeter test to energized equipment.
- Testing through sensitive electronics, surge protectors, or controls without checking their limits.
- Treating one resistance number as a complete diagnosis.
- Ignoring temperature, moisture, cable length, and test duration.
- Touching conductors before the tested circuit has been discharged.
Megohmmeter in Practice: A Real-World Example
After a basement flood, a technician separates feeder cable from the panel and downstream equipment. The technician tests each conductor to ground with a megohmmeter and records the readings. The technician keeps the circuit out of service until insulation results meet applicable requirements.
Sources & Further Reading on Megohmmeter
- Fluke, What Is a Megger and How Does It Work
- National Fire Protection Association, NFPA 70E Standard for Electrical Safety in the Workplace
Related Terms
Resistance
Resistance is the opposition that an electrical material presents to current flow. Measured in ohms, resistance…
Electrical Grounding
Electrical Grounding is a safety system that connects electrical equipment and circuits to the earth or…
Lockout/Tagout
Lockout/Tagout is a safety process that prevents machines, equipment, and electrical systems from releasing hazardous energy…
Line Voltage
Line Voltage is the electrical potential supplied by a power source to a circuit, equipment, or…
Chris Miller Electric
Have Questions About Megohmmeter?
Contact Chris Miller Electric for practical guidance on Megohmmeter and related 24/7 emergency electricians work in Fort Wayne.